Chapter 4 • Disassembly and Power
Lab 4.8 Wall Outlet and Power Cord AC Voltage Check
Objective: To check the voltage from a wall outlet and through a power cord
Parts: Multimeter
Computer power cord
Caution: Exercise extreme caution when working with AC voltages!
Procedure: Complete the following procedure and perform the accompanying activities.
1. Set the multimeter to AC VOLTAGE (refer to the meter’s manual if you are unsure about
this setting). Important: Using a current or resistance setting could destroy the meter.
2. Power on the multimeter. Locate an AC power outlet. Refer to Figure 4.38 for the power
connections.
HotNeutral
Ground
Figure 4.38 AC outlet
3. Insert the meter’s black lead into the round (Ground) AC outlet plug.
4. Insert the meter’s red lead into the smaller flat (Hot) AC outlet plug. The meter reading
should be around 120 volts. Use Table 4.9 to record the reading.
5. Move the meter’s red lead into the larger flat (Neutral) AC outlet plug. The meter reading
should be 0 volts. Use Table 4.9 to record the reading.
Table 4.9 Wall outlet AC checks
Connections Expected voltage Actual voltage
GND to hot 120VAC
GND to neutral 0VAC
Hot to neutral 120VAC