Quick Installation Guide
Rosewill LED T8 Tube
Safety measures must be practiced at all times during the installation of this product. Use proper safety gear and tools for the
installation procedure to prevent personal injury.
Prior to the installation of this product, the installation instructions should be read and completely understood. The installation
instructions must be read to prevent personal injury and property damage. Keep these installation instructions in an easily accessible
location for future reference.
If necessary, consult a professional electric technician or have them perform the retrofit. (service charges may apply)
The following tools will be required for retrofitting: (Not Included)
2x Wire Nuts (or Electrical Tape)
1x Wire Stripper/Cutter
1x Phillips Screw Driver (Option)
!!! CAUTION !!!
Rosewill LED T8 Tube is suitable to be installed in T8 or T12 standard luminaries.
Rosewill LED T8 Tubes cannot be used in retrofitted lamp fixtures which use Ballast and/or starter.
Rosewill LED T8 Tubes are intended to retrofit maximum six lamps, UL Listed surface mount, or fluorescent luminaries with or
without diffuser that use straight tubular lamps. These products are intended to be used in dry or damp locations only.
Instructions
Rosewill LED T8 Tube with universal wide voltage driver are suitable to replace T8 fluorescent tubes in fixtures. To use the Rosewill
LED T8 Tube in an existing T8 fluorescent lamp fixture, a retrofit is required. During retrofit, rewiring is a MUST. Please follow the
installation steps on the following pages.
Retrofit Instructions
Always turn off the power supply from the main circuit breaker first
1. Remove diffuser (if provided) and fluorescent lamp.
2. Open\Remove Wiring Compartment Cover.
Seitenansicht 0
1 2 3 4 5

Inhaltsverzeichnis

Seite 1 - Quick Installation Guide

Quick Installation Guide Rosewill LED T8 Tube Safety measures must be practiced at all times during the installation of this product. Us

Seite 2

3. Cut all wires connected to ballast, and remove or bypass the ballast. Keep the Green wire (ground) to connect with the fixture. 4. Ch

Seite 3

5. Connect Black wire (line) and White / Red wire (neutral) to corresponding wires into each of the lampholders.

Seite 4

6. Close up wiring compartment. 7. Install Rosewill LED T8 Tubes. Ensure the Rosewill LED T8 Tube end labeled AC is inserted into the retrofitted